(1) The voltage protection level Up of SPD should always be less than the impulse withstand voltage Uc of the protected equipment, and greater than the maximum operating voltage Us of the power grid obtained according to the grounding type, that is, Us<Up<Uc. If the line is not shielded, it should be taken into account the line induced voltage, Uc should be considered as 80% of its value.
(2) The leads at both ends of the surge protector SPD and the protected equipment should be as short as possible and controlled within 0.5m.
(3) If the Up of the incoming SPD plus the induced voltage of the leads at both ends and the reflected wave effect are too high compared with the impulse withstand voltage of the protected equipment farther away from it, it needs to be added at this equipment. When the second-level SPD is installed, its nominal discharge current In should not be less than 8/20μs 3kA; when the incoming SPD is not more than 10m away from the protected equipment, if the SPD's Up plus the induced voltage of the leads at both ends is less than the equipment's 80% of Uc, in general, SPD may not be installed at the device.
(4) When there is a switchboard between the SPDs installed according to the requirements of point 3 above, if the Up of the first-level SPD plus the induced voltage of the leads at both ends cannot protect the equipment in the switchboard, it should be installed in the switchboard. The second-level SPD, its nominal discharge current In should not be less than 8/20μs 5kA.
(5) When multiple SPDs are installed on the line, the line length between the voltage switching SPD and the voltage limiting SPD should not be less than 10m, and the line length between the voltage limiting SPD should not be less than 5m. For example, the protected equipment is relatively close to the power distribution center, and more wires can be deliberately wound in the line laying.
(6) When the distance between the surge protector SPD at the incoming end and the protected equipment is greater than 30m, another SPD should be installed as close as possible to the protected equipment, and the current capacity can be 8kA.
(7) When selecting SPD, care should be taken to ensure that the SPD will not be burned due to power frequency overvoltage, because SPD is anti-transient overvoltage, power frequency overvoltage is transient overvoltage (ms level), and the energy of power frequency overvoltage is Hundreds of times the transient overvoltage energy, therefore, care should be taken to select an SPD with a higher power frequency operating voltage.
(8) Protection of SPD: each level of SPD should be protected, or fuses can be used for protection, and the breaking capacity of the surge protector is greater than the maximum short-circuit current at the place.
(9) In addition, when selecting SPD, attention should also be paid to: the response time is as fast as possible; the length of service life, the price factor, the maintainability, the size of the flow capacity, and the humidity resistance.
What if the Connecting Wire of the Lightning Surge Protector is Too Long?November 9, 2021In lightning protection engineering, when arranging surge protectors, the connecting wires are required to be short and straight. However, in many cases at the construction site, the connecting wires ...view
The Role of Lightning and Surge Protection Devices in Biogas PlantsJuly 4, 2024In modern biogas facilities, biogas, as a clean and renewable energy source, is being widely used globally. However, for biogas plants, which process organic materials and produce biogas, the safe ope...view
Protecting Your Business Investments: The Role of Power Surge MonitoringSeptember 11, 2023In today's business landscape, where technology plays a central role in operations, safeguarding your electronic assets is paramount. Power surges, those sudden, unpredictable spikes in electrical...view
Guide to the Function and Selection of Surge Protection Device for LightningMarch 18, 2025As lightning hazards pose increasing threats to buildings and electronic devices, Surge Protection Device for Lightning has become particularly important in modern buildings and power systems. This ar...view
Integrated Lightning Protection Solution: Surge Protector for CCTV CameraJune 26, 2024CCTV video surveillance systems can be used for CCTV video surveillance systems. To ensure that the CCTV video surveillance system can operate continuously and stably, it is essential to integrate lig...view
What Are the Lightning Protection Systems Included in the Security Industry?March 13, 2023To know what lightning protection systems are available in the security industry, we must first understand the development and changes of the security industry. From the emphasis on "no AI, no se...view